Please Wait...

Schiller Cardiovit AT-102 Interpretive EKG with Waveform Display

SKU: 5695-9-070000C
Model: 9-070000C
Your price:  Call or Live Chat For Price

The Schiller Cardiovit AT-102 Interpretive EKG with Waveform Display has the most important Cardiopulmonary Function Tests that are combined in one single device: Resting ECG, Exercise ECG, Spirometry.


Image may be a representation of product

QTY:

Schiller Cardiovit AT-102 Interpretive EKG with Waveform Display Overview

Performance:
  • Intuitive, easy use with direct function keys
  • 12-channel Resting ECG
  • Measurements
  • Interpretation
  • Serial data transfer to PC for storage of both Resting ECG and Spirometry recordings
  • XML data transfer for Resting ECG to PC or Information Systems via Ethernet or modem interfaces (optional)
  • A4-formated (8.5 x11 inches) printouts on internal or external printer
  • Basic Exercise test capability (optional)
  • Possibility for external monitor connection (optional)
Resting ECG
Operating elements:
  • Integrated 3-channel monitor
  • Alphanumeric keyboard
  • Direct keys for the most important functions
  • Easy Print: Integrated high-resolution A4 (8.5 x11 inches) thermal printer, subsequent printout on thermoreactive paper possible
  • Interface for external printer for A4 (8.5 x11 inches) printouts on regular pape
  • • Internal memory for up to 40 records
  • Interface for data-transmission
Exercise ECG
Interface:
  • RS-232 port for peripheral devices such as treadmills,bicycles etc.
Protocols:
  • For exercise ECG, several stand-ard protocols are available for bicycle and treadmill ergometers; the user can either select a standard protocol from a table or define a new protocol
  • J-point settings: J+20,+40,+60,+80 ms; default: +60 ms
Display on the LCD:
  • 3 leads can be selected via direct keys
  • Heart rate
  • ST slope and amplitude (in mV/mV/s) of a lead (the lead can be selected in the set-up; default is V5)
  • Stage,time,and current load
  • Blood pressure (Blood pressure measurement: Automatic – if a bicycle contains an interface for the blood pressure transfer – or manual)
Printouts:
  • Online printout: 6 leads on the internal thermal printer
  • 10-sec.printout: A 10-sec.printout can be initiated at any time on the internal thermal printer
  • Two print formats are available for stage printouts on the internal thermal printer: – 2*6 25 mm/s and 50 mm/s,1 page – 4*3 + 1 rhythm,25 mm/s (50 mm/s), 1 page
  • Final report: All test data is listed in a tabular form
XML Data Transmission (optional)
  • The AT-102 is available with the internal SCHILLER Communication Module (SCM),which transmits Resting ECG data on XML format to a PC or Information Systems via: – Ethernet interface; or – Built-in analogue modem (optional)
  • This enables the AT-102 to be an integrated part of a larger systems solution
  • Secure transmission of patient data via the Internet is possible using 1024-bit strong encryption
  • Equipped with the add-on SCM Server, the SCHILLER Data Management System SEMA-200 can receive the XML output from the SCHILLER Communication Module
Spirometry:
  • Unique SP-250 with disposable sensor to reduce the risk of contamination
  • SP-260 with reusable sensor
  • Simple and fast calibration
  • Memory for up to 40 records
  • Inspiratory and exspiratory test; pre and post medication tests – Selectable predicted value tables – Real-time curves and measurement information on the large screen
Specifications

System:
Dimensions: 400 x 330 x 101 mm,approx. 5 kg
Built-in monitor: 120 x 90 mm effective display area, 320 x 240 dots resolution
On-screen status indicators: Battery status, date, time,power source
Control panel and keyboard: User-friendly, alphanumeric keyboard, LED indicator and LC display
Power supply requirements: 220–240 V (nominal), 50/60 Hz; 110–115 V (nominal), 50/60 Hz; stand-alone operation with built-in rechargeable battery; LED indicator for mains operation, integrated power supply unit
Battery capacity: 4 hours of normal use (approx. 300 automatic ECG printouts or 100 spirometry records)
Power consumption: Max. 30 VA
Line frequency filter: Distortion-free suppression of superimposed 50 or 60 Hz sinusoidal interferences by means of adaptive digital filtering (SCHILLER Powerline Filter SPF) Frequency range of digital recording system: 0 Hz – 150 Hz (IEC/AHA)
Chart paper: Thermo-reactive, Z-folded, 210 mm wide (A4, 8.5 x 11 inches)
Printing process: High-resolution thermal head printer,8 dots/mm (amplitude axis), 40 dots/mm (time axis) @ 25 mm/s
Interfaces: RS-232 interface to connect spirometry sensor, data transmission to PC (SEMA-200) and external modem connection; parallel port for external printer; optional Ethernet interface and optional internal modem for XML data transmission
Memory: Possibility to save up to 40 Resting ECG or Spirometry measurements
Environmental conditions:
– Temperature, operating: 10° to 40°C
– Temperature, storage: -10° to 50°C
– Relative humidity: 25 to 95% (no condensation)
– Pressure during operation: 700 to 1060 hPa

Safety Standards:
Safety Standards: IEC/EN 60601-1; UL 60601-1; C22.2 No. 601.1-M90; IEC/EN 60601-2-25; IEC/EN 60601-1-2 (EMC)
Protection Class: I according to IEC/EN 60601-1 (with internal power supply)
Applied Part: CF according IEC/EN 60601-1
Conformity: according Directive 93/42/EEC (Medical Devices)
Classification: IIa according Directive 93/92/EEC

Technical Data for ECG:
Patient input circuit: Fully floating and isolated, defibrillationprotected (only with original SCHILLER patient cable)
Monitor display:
– 3-channel display of the selected leads
– 25, 50 mm/s
– 5, 10,20 mm/mV
– Filter status (on/off)
– Insufficient electrode contact
– Heart Frequency, HF
– mm/mv,mm/s
Leads: 12 simultaneous leads: Standard / Cabrera
Chart printout speed: 5/10/25/50 mm/s (manual print)
Sensitivities: 5/10/20 mm/mV, either automatically adjusted or manually selected
Automatic lead programs:
– 6/12-channel presentations of 12 simultaneously recorded standard leads on one or more A4 (8.5 x 11 inches) pages
– Numerous printout formats can be selected
Data record:
– Patient data (name, age, height,weight, BP), user ID
– Listing of all ECG recording conditions (date, time, filter)
– Measurement program (M): ECG measurements results (intervals, amplitudes, electrical axes), average complexes with measurement reference markings
– Interpretation (C) with adult and pediatric guidance
Recording track: 6/12-channel presentation, optimal positioning on a width of 200 mm,automatic baseline adjustment
Filter: Myogram filter (muscle tremor filter): 25 Hz or 35 Hz, can be switched on/off (SCHILLER Baseline Stabilizer SBS , SCHILLER Smoothing Filter SSF)
ECG amplifier:
– Simultaneous recording of all 9 active electrode signals (= 12 leads)
– Sampling frequency: 1000 Hz
– Pacemaker detection: 2 mV/ 0,1 ms

Technical Data for Spirometry (Option):
Measured values:
FVC: FVC, FEV0.5,FEV1.0, FEV3.0, FEV0.5/FVC, FEV1,0/FVC, FEV3.0/FVC, FEF0.2-1.2, FEF25-75%, FEF75-85%, PEF, FEF25%, FEF50%, FEF75%, FIVC, FIV1.0 , FIV1.0/FIVC, FIV1.0/FVC,PIF, FIF50%, FMFT
SVC: SVC, ERV, IRV,TV
MVV: MVV, RR,TV
Presentation possibilities (printout and screen):
– Flow/volume graph
– Volume/time graph
– Table of measured values
– Realtime flow curve
Data record:
– Patient data (name, age, height,weight), user ID
– Registration conditions (date, time, date of last calibration)
– Flow/volume graph and/or volume/time graph
– Table of measured values with PREDICTED/ACTUAL/ DIFFERENTIAL values
– Diagnosis guidance
– Memory for more than 60 ECGs or spirometry records
Prediction equation:
Adults: ECCS,Austria, Crapo, Morris, Knudson, Knudson76, Polgar, Berglund, Finland, India, Composite
Children: Quanjer & Tammeling,Austria, India, Knudson, Knudson76, Polgar
Extrapolated predicted values Comparison of PRE/POST medication is possible
Standards Compliance: ATS, OSHA, NIOSH

SPIROVIT SP-250 Pneumotach Flowsensor for pulmonary function testing with disposable mouthpiece:
Dimensions of SP-250: 118 x 36 x 28 mm,approx. 120 g; 4.6 x 1.4 x 1.1 in.,approx. 0.26 Ibs
Measuring method: Pneumotachometer
Measuring accuracy: According ATS < 3%
Flow impedance: < 0.2 mbar*s/l at 12 l/s
SPIROVIT SP-260 Pneumotach Flowsensor for pulmonary function testing with reusable mouthpiece:
Dimensions of SP-260: 125 x 36 x 28 mm,approx. 160 g; 4.9 x 1.4 x 1.1 in.,approx. 0.34 Ibs
Measuring method, Measuring accuracy, Flow impedance same as SP-250
Scope of delivery:
– 1 pneumotach sensor; choice of SP-250 disposable (P/N 2.100022) or SP-260 reusable sensor (P/N 2.100551)
– Accessories: 2 noseclips and either 1 pack of disposable plastic mouthpieces for SP-250 (P/N 2.100077) or 1 pack
of disposable filters for SP-260 (P/N 2.100123)
– 1 operating manual

Scope of delivery for CARDIOVIT AT-102 Standard:
CARDIOVIT AT-102 Resting ECG with 12 simultaneous leads, pacemaker detection,automatic ECG measurement
Accessories:
– 1 10-lead patient cable
– 1 set of electrodes or disposable electrodes
– 1 power cable
– 1 pack chart paper
– Operating manual
Software options:
– Computer-aided ECG interpretation for pediatric and adult ECGs (C)
– Basic exercise test
– SEMA-200 PC software to save, validate and archieve ECG and spirometry data on PC
Hardware options:
– Equipment trolley
– Spirometry sensor SP-250 or SP-260
– Calibration syringe
– Vacuum electrode system VAC-100
– External printer
– External monitor connection
– Internal SCHILLER Communication Module with optional built-in analogue modem

*Technical Data are subject to change without notice.

ConditionNew
Manufacturer Schiller

Write a Review

Rating  



Name  
Email Address  
Review  

My Cart

You currently have 0 Products in your shopping cart.

Rest Assured...

Found a Lower Price?
We will beat it! Call 800.335.3774 for our Price Match Guarantee.

Why buy from MedSupplier.com?
  • Authorized Dealer
  • Price Match Guarantee
  • Knowledgable Sales Reps
  • No Black Market Products

We do what those other guys can't by being an authorized dealer and providing knowledgable sales representatives and an experienced customer service team.

There are no black market products in our catalog because they come straight from the manufacturer, so you know you are getting a geniune product.