The EasyOne Plus is an easy-to-use diagnostic spirometer that can perform a full range of tests (FVC, FVL, MVV). It works well in primary care, industrial, hospital, and specialty physician situations. It is very accurate. The digital ultrasonic flow measurement gives fast and reliable results. This unit meets the 1994 ATS recommendations for diagnostic spirometry and also meets the NIOSH/OSHA and SSD guidelines. An automated comparison to predicted values (NHANES III, Knudson, Morris, Crapo, Dockery, Hsu) pre/post comparisons, and interpretation of results. This unit has automated QC and a graphic curve display.
NDD Advantage:
- not influenced by temperature, humidity or barometric pressure
- no calibration, simple 3L cal-check
- no cleaning, no maintenance
- simple and economic consumables
- easy to operate with simple operator prompts
- high accuracy for low flows
- no down time
- toll free technical support
- 3 year exchange warranty
NDD TrueFlow Technology
- ultrasound transit time measurement
- ndd true flow is absolute flow (not influenced by
contamination, humidity, droplets or temperature)
- ndd true flow is used as OEM for major manufacturers
(ventilators, anesthesia, spirometers, etc....)
Display
- 5 lines of clear text
- guidance: Quality Assurance and Quality Grades
- instant results and interpretation
Proven worldwide
- by NASA, MIR programs for crew monitoring in space
- ATS, ERS, CSA, JAPAN, FDA, CE, NIOSH,
OSHA,GOLD, BOLD, Platino, NLHEP
- pharmaceutical, clinical and marketing studies
- top references in USA, EU, Japan, Asia,
Australia, Latin America, Canada
Keypad
- alpha-numeric
- data entry like cell phone
Cradle (base station)
- for standby positioning of EasyOne™ Plus
- for communication with EasyOne™ Plus
- direct to printer
- direct to PC with EasyWare™
or EasyWare™ Lite
EasyOne Plus Screen™ PC connection
- real-time FV and VT curves
- pediatric incentive
Battery powered
-
2 AA standard batteries last
for approximately 400 tests
- no recharging, no down time
- works everywhere, any time
Low operating costs
-
no calibration (simple 3L cal-check)
- no maintenance
- no down time
Spirette
-
simple, comfortable fit for adults and children
- hygienic, single patient use disposable for
contamination control
- no sensor elements
Vast memory
-
up to 700 subjects (first in - first out)
- secured memory, no accidental loss due to low battery
- multiple units may be used with one cradle and single
copy of EasyWare™ PC software
Report
-
plain paper, letter size, color or greyscale print
- direct USB connection
- export to 'excel', ascii, xml, etc...
- Pictbridge compatible
What are the differences between the new EasyOne Plus and the old EasyOne?
- Pictbridge Printer Compatability
- FVL Tidal Breathing
- 8 Trials Instead of 4 Trials
- EasyWare Lite
- Same light-weight portability with a new modernized look and feel
Dimension: |
3.3" x 6.2" x 1.7" |
Weight: |
9 ounces |
Measuring Accuracy: |
Volume: ± 2% or 0.050 l
Flow: ± 2% or 0.020 l/s
PEF: ± 5% or 0.0200 l/s
MVV: ± 5% or 5 l/min |
Resolution: |
Volume: > 1 ml
Flow: 4 ml/s |
Measuring range: |
Volume: ± 12 l
Flow ± 16 l/s |
Resistance: |
approx. 0.3 cm H2O/l/s |
Data entry: |
14-key keyboard |
Power supply: |
(2) AA batteries |
Battery service life: |
400 tests approx. |
Data memory: |
700 tests approx. |
Print out: |
direct to printer or via PC, plain paper |
Data communication: |
direct: printer with EasyWare™ and EasyWare Lite to PC and beyond |
Languages: |
English, French, Spanish, Italian, German |
Predicted values: |
NHANES III, Knudson 1976, Knudson 1983, Crapo, Morris, Cherniak, Berglund, ERS (ECCS), Roca, Austria, Gulsvik, Hedenstroem
Pediatrics: Zapletal, Dockery, Hsu, Polgar |
|
Diagnostic |
Frontline |
Test modes |
FVC (expiratory), F/V Loop (inspiratory and expiratory), slow VC, MVV, Pre-Post measurement. Unit can be configured to meet NIOSH/OSHA and Disability reporting requirements. |
FVC (expiratory), Pre-Post measurement |
Parameters |
FEV1, FVC, FEV1/FVC, FEV6,
FEV1/FEV6, FEF25-75, FEF25,
FEF50, FEF75, PEF, FET, FIVC, PIF,
IVC, IRV, ERV, FEV1/VC, MVV,
pre-post % variation, QC rating |
FEV1, FEV6, FEV1/FEV6, FVC,
FEV1/FVC, PEF, pre-post %
variation, QC rating |
Quality control |
Requires 3 acceptable, reproducible
maneuvers. (meets ATS
standards) |
Requires 2 acceptable, reproducible
maneuvers. (meets NLHEP
standards) |
Automatic Quality control |
Quality control can also be overridden
manually. |
Automatic control is always active. |
Trial storage and display |
Can store and display the best,
or the best 3 trials, including
curves. |
Stores and displays only the best
trial and curve. |
Report Configuration |
Report can be customized for
curve type and size. |
Report is fixed, showing the
smaller sized FV and VT curves. |
Predicted Values |
Can choose from several sets of
adult and pediatric normals. |
NHANESIII normals only are used. |
Curve Display |
Displays a full flow-volume
curve on the display after each
trial. |
Displays only numerical results. |
|