Burdick Atria 3100 Interpretive EKG Overview
The lightweight and compact device operates
either manually or automatically, printing 3-, 4-,
6- or 12-lead ECG tracings. The combination of
a standard QWERTY keyboard and dedicated
function keys make the Atria 3100 easy to use.
The Atria 3100 also features advanced
functionality, including Burdick's exclusive
AccuPrint™ functionality, which restricts ECG
printing if lead wires are not attached properly.
Simple to use, compact and reliable, the Burdick Atria 3100 EKG is the ideal choice for the physician's office. The Burdick Atria 3100 collects the same high-quality 12-lead ECG tracings as higher priced models at a price that even small practices
can afford.
Big Functionality In A Small Package
- Automatic or manual operation
facilitates STAT operation.
- High resolution thermal printer prints
on standard size or A4 paper for easy
reading and storage.
- A variety of printout choices, including
3-, 4-, 6- or 12-lead ECG printouts and
3-, 4-, 6- or 12-lead rhythm printouts,
to suit the requirements of your
practice.
- Extended life battery allows you to
print up to 300 pages of continuous
rhythm between recharges.
- Data storage for 50 ECGs.
Atria 3100 Advanced Features Improve Accuracy
- AccuPrint restricts ECG printout when
leads are not properly attached.
- STABLE baseline filter decreases the
level of artifact by assuring that the ECG
baseline is stable with no distortion of
ST measurements.
- Pacemaker algorithm accommodates
patients with pacemakers.
- Choice of QTc calculation formulas
includes Hodges, Bazett, Framingham
and Fridericia.
- Beat-to-beat R-R intervals may be
printed out on reports.
Intuitive Operation Saves Time
- Alphanumeric keyboard with intuitive
menu selections simplifies operation.
- Backlit LCD screen is easy to read, even
in low light situations.
- Easy loading paper saves time.
Upgrade Options To Suit Your
Changing Needs
With a variety of upgrade paths, the
Atria 3100 ECG will expand and change
with growing needs.
- Units purchased without Burdick's
powerful interpretation option can be
upgraded at any time.
- Communications upgrade options
allow the Atria 3100 to communicate
by fax, modem and Ethernet as well
as wireless Bluetooth® and 802.11.
The communications options can be
added to the Atria 3100 after the initial
purchase.
A Second Opinion That You Can Count On
The Burdick Atria 3100 utilizes the proven
University of Glasgow algorithm, for
interpretation, providing a silent second
opinion. Unlike competitive products,
which limit algorithm criteria to age,
the University of Glasgow algorithm,
developed in the 1970s and continuously
updated, bases its analysis on five
clinically significant criteria: gender, age,
race, medication and classification.
This is critical because ECG results for
patients with different demographic
profiles and medical conditions can vary
greatly. For example, subtle T-wave
changes that are considered abnormal
for a white male are considered normal
for a black male of the same age. An ECG
that would represent LVH in a 50-year-old
female may be normal for a 50-year-old
male. These are two examples of the
many clinical issues that can arise when
analyzing without the five criteria.
Communications Options
For physicians looking for a traditional
ECG and advanced communications with
electronic storage feature, the Burdick
Atria 3100 ECG with communications
options combines the best of both
worlds.
Flexible Connectivity Options
The Atria 3100 offers cutting-edge
communications capabilities, including
wired Ethernet and wireless 802.11.
Advanced encryption tools ensure the
highest level of data transmission security.
Bi-directional Communication with HeartCentrix
The ideal choice for device integration
with your EMR. Download orders with
patient demographics from your EMR.
Upload test results back to HeartCentrix.
The reports can then be viewed, edited
and confirmed from the patient's chart
in the EMR.
Transmit Test Results via XML
Test results can be electronically
transmitted from the exam room to your
network and EMRs through an XML data
transfer. Discrete data and a PDF of the
report can be sent. No more scanning
and keeping hard copies. Imagine the
convenience of attaching an ECG report
to the patient's electronic medical
record, keeping all information in
one file.
E-mail Colleagues Test Results
E-mail capability allows you to send test
results directly from the Atria in a PDF
format to colleagues for collaborative
efforts. The industry-accepted diagnostic
quality PDF allows any recipient to
review results without purchasing
proprietary software.
Print Test Results to Plain-paper Printer
Send results wired or wirelessly from
the exam room to a network or
standalone plain-paper printer using
options 802.11, USB, Bluetooth, or
Ethernet. The diagnostic-quality printouts
contain all the information found on the
traditional thermal paper printouts.
FAA Compliant
Atria 3100 with advanced
communications includes modem
transmissions that comply with FAA
system requirements for ECG testing.
Warranty and Service Offerings Protect Your Investment
With warranty and service offerings we
help protect your investment from
unforeseen service costs. The Atria 3100
has a 3-year warranty when the warranty