The lightweight and compact device operates either manually or automatically, printing 3-, 4-, 6- or 12-lead ECG tracings. The combination of a standard QWERTY keyboard and dedicated function keys make the Atria 3100 easy to use.
The Atria 3100 also features advanced functionality, including Burdick’s exclusive AccuPrint™ functionality, which restricts ECG printing if lead wires are not attached properly.
Simple to use, compact and reliable, the Burdick Atria™ 3100 ECG is the ideal choice for the physician’s office. The Burdick Atria 3100 collects the same high-quality 12-lead ECG tracings as higher priced models at a price that even small practices can afford.
A Second Opinion That You Can Count On The Burdick Atria 3100 utilizes the proven University of Glasgow algorithm, for interpretation, providing a silent second opinion. Unlike competitive products, which limit algorithm criteria to age, the University of Glasgow algorithm, developed in the 1970s and continuously updated, bases its analysis on five clinically significant criteria: gender, age, race, medication and classification. This is critical because ECG results for patients with different demographic profiles and medical conditions can vary greatly. For example, subtle T-wave changes that are considered abnormal for a white male are considered normal for a black male of the same age. An ECG that would represent LVH in a 50-year-old female may be normal for a 50-year-old male. These are two examples of the many clinical issues that can arise when analyzing without the five criteria.
Communications Options For physicians looking for a traditional ECG and advanced communications with electronic storage feature, the Burdick Atria 3100 ECG with communications options combines the best of both worlds.
Flexible Connectivity Options The Atria 3100 offers cutting-edge communications capabilities, including wired Ethernet and wireless 802.11. Advanced encryption tools ensure the highest level of data transmission security.
Bi-directional Communication with HeartCentrix The ideal choice for device integration with your EMR. Download orders with patient demographics from your EMR. Upload test results back to HeartCentrix. The reports can then be viewed, edited and confirmed from the patient's chart in the EMR.
Transmit Test Results via XML Test results can be electronically transmitted from the exam room to your network and EMRs through an XML data transfer. Discrete data and a PDF of the report can be sent. No more scanning and keeping hard copies. Imagine the convenience of attaching an ECG report to the patient’s electronic medical record, keeping all information in one file.
E-mail Colleagues Test Results E-mail capability allows you to send test results directly from the Atria in a PDF format to colleagues for collaborative efforts. The industry-accepted diagnostic quality PDF allows any recipient to review results without purchasing proprietary software.
Print Test Results to Plain-paper Printer Send results wired or wirelessly from the exam room to a network or standalone plain-paper printer using options 802.11, USB, Bluetooth, or Ethernet. The diagnostic-quality printouts contain all the information found on the traditional thermal paper printouts.
FAA Compliant Atria 3100 with advanced communications includes modem transmissions that comply with FAA system requirements for ECG testing.
Warranty and Service Offerings Protect Your Investment With warranty and service offerings we help protect your investment from unforeseen service costs. The Atria 3100 has a 3-year warranty when the warranty card is returned.
Dimensions: 15.0" x 13.125" x 5.5" (381 x 334 x 140 mm) Weight: 11 lbs (5 kg) (including external power supply) Display: Backlit 2 x 40 character LCD Keyboard: Full alphanumeric keypad plus designated quick keys Data storage: 50 records
Network connection Wired: 10/100 MBPS Ethernet via RJ45; Wireless: 802.11g (compatible with 802.11b networks), security options including WEP (64/128 bit), WPA / WPA2 (Personal and Enterprise, including AES), EAP-TLS, PEAP/MSCHAPv2, LEAP, RADIUS servers (including Microsoft IAS, Cisco ACS and Cisco Aironet 1200), roaming across WAPs of various configurations and support for mixed 802.11 / Ethernet networks.
Power requirements AC operation: 115/230 V AC +/-10%, 50/60 Hz at external power source; Battery operation: 14.4 V NiMH rechargeable battery pack; Battery duration: 300 pages continuous printing without communications option
Printout Printout device: 216 mm thermal dot array; Paper dimensions: 8-1/2 x 11 (US letter) or A4; Paper type: Thermal sensitive (Burdick Assurance® or Heartline™ paper recommended); Chart speeds: 12.5, 25, 50 mm/sec; Gain: 5, 10, 20 mm/mV Chest or Limb (may be split); Printout formats: 3-, 4-, 6-, or 12-channel; additional rhythm formats
Acquisition Lead selection: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6, V4R; supports Cabrera and alternate chest lead (chest lead selection V2R thru V9R + V7,V8,V9); Measurement (standard), Interpretation (optional): Diagnosis, measurements and reason statements based on five demographic criteria; Meets IEC 60601-2-51; Pacemaker display capability: meets or exceeds ANSI/AAMI EC11-1991; Modes: Automatic, rhythm or manual; Frequency response: Meets or exceeds ANSI/AAMI EC11-1991 standard; Input impedance: Meets or exceeds ANSI/AAMI EC11-1991 standard; Electrode offset tolerance: +/- 300 mV; A/D conversion: 8,000 samples/second, 2.5 µV LSB RTI; Artifact filter response: 40 Hz, -3db; Data storage resolution: 500 samples/second, 2.5 µV LSB RTI
Environmental Specifications Operating temperature: 50°F to 104°F (10°C to 40°C); Operating relative humidity: 20% to 90%, noncondensing; Operating atmospheric pressure: 1060 hPa to 700 hPa (-500 ft to 10,000 ft reference to sea level); Storage temperature: -4°F to 115°F (-20°C to 45°C); Storage relative humidity: 10% to 90%, noncondensing; Storage atmospheric pressure: 1060 hPa to 190 hPa (-500 ft to 40,000 ft reference to sea level)
Conforms to standards ANSI/AAMI EC11-1991 EN 60601 CAN/CSA C22.2 no. 0-M91 EN 60601-1-2:2001 CAN/CSA C22.2 no. 601.1S1 UL 60601-1 CAN/CSA C22.2 no. 601.2.25, Amend. 1 EN 60601-2-51:2003 CAN/USA C22.2 no. 601.1-M90 EN 60601-1-4:2000
Safety Leakage current: Patient <10 µA, chassis <100 µA; Defibrillation protection: to 5000 V, 360J