ECG Monitoring
Patient Connection: 3-lead ECG cable.
Input Selection: Fully defibrillator protected.
ECG Size: Automatic Control (AUD) gain.
Heart Rate: 30-300 bpm ±5%.
Display
Screen Type: High-resolution LCD display.
Screen Size: 3.02 inches W x 2.27 inches H.
Sweep Speed: 25 mm/sec.
Viewing Time: 3 seconds.
Displayed Information: Heart rate, ECG waveform, text prompts, CPR bar graph, battery gauge, elapsed time, number of shocks delivered.
Event Documentation
Type: Internal non-volatile memory.
Memory Capacity: With audio recording enabled, 20 minutes of ECG and operator and device actions; Without audio recording, 7 hours of ECG data or up to 4 patient records. Unlimited data storage with USB key.
Event Review & Reporting: RescueNet™ Code Review software version 3.30 or higher.
Communications: IrDA infrared wireless for communication with personal computer.
Defibrillator
Waveform: ZOLL Rectilinear Biphasic™ waveform.
Energy: 50, 70, 85 (pediatric), 120, 150, 200 joules (adult) preconfigured.
Charge Time: Less than 10 seconds with a new fully charged battery. Depleted batteries will result in a longer defibrillator charge time.
Energy Display: Monitor display indicates selected energy in manual mode only.
AED Function: Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts.
Electrodes: CPR-D•padz, stat•padz II™, and Pediatric pedi•padz II™ packaged in pairs. CPR-D•padz one-piece electrode provides feedback on rate and depth of chest compressions.
Manual: Energy selection user configurable, 120, 150, 200 J adult and 50, 70, 85 J pediatric.
Semi-Automatic: Evaluates electrode connection and patient ECG to determine if defibrillation is required.
Shockable Rhythms: Ventricular fibrillation with amplitude >100 uV and wide complex ventricular tachycardia with rates greater than 150 bpm (adult) and greater than 200 bpm (pediatric).
Defibrillation Pads Impedance
Measurement Range: 10-300 ohms.
Prompts: Audible voice prompts and text messages guide user through complete sequence of operation.
Controls: ON/OFF, Shock, Softkeys.
Battery Options
Type: Rechargeable, sealed lead acid.
Recharge Time: 4 hours or less with a ZOLL Power-Charger 4x4 or 1x1 Battery Charger.
Operating Time: For a new, fully charged battery pack at 20º C: 170 defibrillator discharges at maximum energy, or 6 hours continuous ECG monitoring.
Type: Sealed, disposable lithium manganese.
Operating Time: 300 defibrillator charges at maximum energy or 13 hours continuous ECG monitoring.
General
Size: 3 in (7.6 cm) x 9.2 in (23.5 cm) x 9.4 in (23.9 cm) deep.
Weight: < 6.5 lbs with disposable battery and electrodes (2.9 kg).
Design Standards: Meets or exceeds AAMI DF-80, EN 60601-1, EN 60601-1-2.
Patient Safety: All patient connections are electrically isolated.
Environmental
Operating Temperature: 0º C to 50º C.
Storage and Shipping Temperature: -30º C to 70º C.
Humidity: 10% to 95% relative humidity, non-condensing.
Vibration: MIL Std. 810F, Minimum Helicopter Test.
Shock: IEC 68-2-27; 100G.
Material/Water Ingress: IEC 60529, IP55.
Electromagnetic Compatibility (EMC): CISPR; 11 Class B Rated and Conducted Emissions.
Electromagnetic Immunity: AAMI DF-80; IEC 60601.
Electrostatic Discharge: IEC 61000-4-2.
Conducted Susceptibility: IEC 61000-4-6.