Quick, Easy to Use and Affordably Priced
Welch Allyn Spot Vital Signs has made its mark in
ambulatory and acute care settings for its accuracy,
durability and cost-effectiveness. Now with updated
features, the fully automated, multiparameter
Spot Vital Signs has become the device of choice
for frontline caregivers world-wide.
Check vital signs rapidly, automatically—and affordably—with the new Spot Vital Signs
Hospital-grade equipment now offers enhanced clinical performance and quality.
- Fast and accurate—completes BP, pulse rate, temperature,
and SpO2 in approximately 30 seconds
- Multiparameter and modular so you can select precisely
the vital signs you need
- Optional Masimo® or Nellcor® pulse oximetry
- Optional SureTemp® thermometry
- IR connectivity to interface with computerized patient records
- Portable—carry it, wheel it, or mount it
- Big, bright, easy-to-read LCD screen
- Offers you one of the lowest priced multiparameter
instruments on the market
- Fully upgradeable to meet your changing needs
- Integrated long-life battery enhances portability
and continuous operation
Connect to patient records
IR connectivity to interface with
electronic patient records
Fast and accurate readings
Increase productivity in high-volume,
fast-paced settings
Easy to learn and simple to use
Intuitive design and training materials provide
concise, easy training for your staff
Affordable, multiparameter functionality to meet your vital signs needs
Standard Features:
Blood Pressure
Noninvasive blood pressure
using the oscillometric method.
Pulse rate and Mean Arterial
Pressure included.
Optional Features:
Temperature
SureTemp® thermometry gives
you the versatility to obtain oral,
axillary and rectal temperatures
with the speed you want and
accuracy you demand
- Oral—approx. 4 seconds
- Axillary—approx. 10 seconds
- Rectal—approx. 15 seconds
Pulse Oximetry
Spot Vital Signs can be
configured with the latest pulse
oximetry technology from either
Masimo or Nellcor for accurate
SpO2 and pulse rate readings.
IR Connectivity
Data can be transferred from
the device into patients’ medical
records via the IR connection.
Welch Allyn Spot Vital Signs Specifications
Noninvasive Blood Pressure (NIBP)
Cuff Pressure Range
0 to 300 mmHg
Initial Cuff Inflation
160 mmHg (adjustable)
Systolic Range
60 to 250 mmHg
Diastolic Range
30 to 160 mmHg
Mean Arterial Pressure Range
40 to 190 mmHg
Blood Pressure Accuracy
Blood pressure meets or exceeds SP10:1992 AAMI standards
Blood Pressure Determination
Time 20-45 seconds typical
Overpressure Cutoff
315 mmHg ± 15 mmHg
Pulse Rate Range (using BP determination)
40 to 200 bpm
Pulse Rate Accuracy (using BP determination)
± 5%
Temperature
Measurement Range
86 °F to 109.4 °F (30 °C to 43 °C)
Calibration Accuracy
± 0.2 °F (± 0.1 °C) (Monitor Mode)
Determination Time
Oral—Approximately 4 seconds
Axillary—Approximately 10 seconds
Rectal—Approximately 15 seconds
Probe
Oral/Axillary—Blue cap
Rectal—Red cap
SpO2
Performance Measurement Range
70% to 100%
Pulse Rate Range
25 to 240 bpm
SpO2 Accuracy
Masimo: ± 2 digits
Nellcor: ± 3 digits
Pulse Rate Accuracy
Masimo: ± 3 digits
Nellcor: ± 3 digits
Mechanical
Dimensions
Height: 9.7 in (24.6 cm)
Length: 5.7 in (14.5 cm)
Depth: 4.7 in (12.0 cm)
Weight
Approximately 4.6 lbs (2.1 kg)
Electrical
AC Power Supply
7.2 V DC at 1.0 A
Rechargeable sealed lead acid internal battery
Battery Recharge Time
90% to 100% after 12 hours
Simultaneously operates device and charges battery when
AC power adapter is plugged in
Operating Time
A fully charged battery supports 150 typical blood pressure
determinations at 7-minute intervals
Environmental
Operating Temperature
50 °F to 104 °F (10 °C to 40 °C)
Operating Relative Humidity
15% to 90% (noncondensing)
Operating Altitude
-557 ft to +16,000 ft (-170 m to +4,877 m)
Storage Temperature
-4 °F to 122 °F (-20 °C to 50 °C)
Storage Humidity
15% to 90% (noncondensing)
EMC Standard
IEC/EN 60601-1-2
Warranty
Two-year warranty on parts and labor