General
Weight: 13.5 lbs (6.1 kg) (basic configuration)
Size: 16.7 x 12.5 x 5.3 inches; 41.75 x 32 x 13 cm
Operating:
> Time: 2 hours
> Temperature*: 0 to 45° C
> Humidity* (NC): 15 to 95% RH
> Vibration*: MIL-STD 810E
> Shock / Drop*: MIL-STD 810E
> Altitude: Up to 15,000 feet
Transport and Storage: Temperature (-30 to 70˚C), humidity (15 to 95% non-condensing), atmospheric pressure ( 860 to 1060 hPa), shock/vibration (ISTA 1A)
Enclosure Protection*:
> Solid Foreign Object: IEC 529, IP2X
> Water: IEC 529, IPX4
Operating Power: Battery pack or auxiliary power supply
* All tests performed per AAMI DF-2 Defibrillation Standard
Defibrillator
Waveform:
> Biphasic: Low current, impedance compensated, optimized terminating current, truncated exponential biphasic
Energy Select:
> External: 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 J
> Internal: 2, 3, 4, 5, 6, 7, 8, 9, 10, 20, 30, 50 J
Charge Time:
< 7 seconds @ 360 J (with a charged battery)
< 15 seconds @ 360 J (no battery, 90% AC mains voltage)
Charge Indicator: Audible and graphic
Output: Adult paddles, internal paddles, peds adapter and multipurpose hands-free adapter available
Synchronizer: Delivers energy within 60 msec
Disarm: Front panel switch
Power
Mains Voltage: 100-240VAC (auto ranging)
Mains Frequency: 50/60Hz
Battery – (User replaceable)
Type: NiCad 12 volt
Low Battery Indicator: Low battery icon on display
Multiple Paired Contacts: Ensures quick, error-free insertion and backup reliability
Recharge Rate: 80% in 3 hours. 100% in 4 hours
Display
Input: 3-lead or 5-lead patient cable, paddles, or multipurpose hands-free adapter
Size: 6.4 inch (16.5 cm) diagonal, non-fade
Type: LCD color
Display Resolution: 640 x 480 pixels
Sweep Speed: 25 mm / sec
Lead Selections: Paddles (Pads), I, II, III, AVR, AVL, AVF, V
Frequency Response: (User-selectable)
2 to 20 Hz Limited mode
0.5 to 40 Hz Monitor mode
0.05 to 150 Hz Diagnostic mode
(automatically sets chart recorder response)
Common Mode Rejection: Complies with AAMI EC13-1992 section 3.2.9.10
Heart Rate Meter: 20 to 300 BPM
Heart Rate Alarms: User-selectable
Size: 0.125, 0.25, 0.5, 1, 2, 4 cm/mv and auto-ranging
Recorder
Type: High-resolution thermal array
Annotation: Time, date, ECG lead, ECG gain, heart rate, defibrillation and pacing
parameters and treatment summary ACLS events
Paper Width: 50 mm
Paper Speed: 25 mm/sec
Delay: 6 seconds
Frequency Response: Automatically set to monitor's frequency response
Treatment Summary: Records defibrillation, pacing and status events. Automatically
logs into memory the type of event, time and ECG sample
Tx Summary Log: 28 ECG events or 300 non-ECG events
Record Modes: Manual and automatic
Pacer
Type: External transcutaneous pacing
Pacer Rate: 30 to 180 BPM ± 5%.
Output Current: 30 to 180 mA ± 10% or 5 mA (whichever is greater)
Modes: Demand and asynchronous
Status Indicators: ECG lead fault, pace lead fault, pace marker on monitor and chart, start/stop LED
Pulse Type: Rectangular, constant current
Pulse Width: 20 ms
Refractory Period: 250 ms
Output Protection: 360 Joules
Advisory Module (option)
Operation: Push button initiates a single ECG analysis cycle. Advises defibrillation on VFIB or shockable VTACH
Analysis Time: 4-16 seconds
Outputs: Visual Display of Analysis results and prompts
Visual Prompts: “Analyzing – Stand Back”, “No Shock Advised”, ”Shock Advised”, “Motion Detected”, “Lead Fault”, “Attach Defibrillator Pads”
Option upgrade capability: Unit can be upgraded to add an advisory option in the field
Certification
North American certification: UL and cUL