Why compromise Performance and Reliability when you can have it
all in one affordable ECG-System? The AT-2 is a low cost ECG system with
performance features previously only available in high priced systems. Using the
latest design and manufacturing technology, the AT-2 provides A4 reports within
seconds at the touch of a button. Optional is an automatic measurement and
interpretation program as well as a trolley.
Features
- Full-size A4 reports to fit patient charts
- Powerful battery, which lasts for 400 recordings or 6 hours continuous
use
- Built-in thermal printer
- Up to 20 different printout formats
- Realtime printout of 6 channels with 5, 10, 25 oder 50 mm/s
- Various recording rates
- Simultaneous 12 lead ECG acquisition
- Printouts in less than 20 seconds for immediate analysis
- Auto printout of all 12 channels on 1 or 2 pages
- Copy function for unlimited number of copies
- AC/DC power supply with built-in rechargeable battery, built-in charger
unit
- Portable – weighs only 4.8 kg
- CE labelled
- Meets or exceeds U.S. and international quality standards
Specifications
Dimensions: 400 x 330 x 101 mm, approx. 4.8 kg
Power supply requirements: 220 – 240 V (nominal), 50/60 Hz or 100 – 115
V (nominal), 50/60 Hz independent operation with built-in rechargeable
battery, LED indication for mains and battery, built-in charger unit
Power consumption: Max. 28 VA
Battery charging time: 15 hrs. from a completely discharged battery, 3
hrs. to 60 % capacity
Battery capacity: 6 hrs. of normal use or 400 automatic ECG printouts
Frequency range of digital recorder: 0 Hz – 150 Hz (IEC/AHA)
Patient input circuitry: Fully floating and isolated, defibrillation
protected (only with original SCHILLER patient cable)
Control panel and keyboard: User-friendly key pad, LED indicators
LED indicators:
> Lead group
> Mains connected
> Battery operation and low battery (indicator flashes)
> Paper tray empty or jammed
> Filter status (on/off)
> Loose electrodes
Leads: 12 simultaneous leads: Standard / Cabrera
Myogram (muscle tremor) filter: Adjustable at 25 or 35 Hz (also for
copy function)
Line frequency filter: Distortion-free suppression of superimposed 50
or 60 Hz sinusoidal interferences by means of adaptive digital filtering
ECG amplifier:
> Simultaneous, synchronous recording of all 9 active electrode signals (= 12
leads)
> Sampling frequency: 1000 Hz
> Pacemaker detection: Amplitudes from ± 2 to ± 700 mV and pulse widths from
0.1 to 2.0 ms
Printing (built-in thermal printer):
Paper speed: 5 / 25 / 50 mm/s (manual printout)
Sensitivities: 5 / 10 / 20 mm/mV, either automatically adjusted or
manually selected
Chart paper: Thermoreactive, Z-folded, A4 (letter size), perforation
each page, approx. 60 m
Printing process:
> High-resolution thermal printhead
> 8 dots per mm / 200 dots per inch (amplitude axis)
> 40 dots per mm / 1000 dots per inch (time axis) @ 25 mm/s
Automatic lead programs: 6/12 channel representation of 12
simultaneously acquired standard leads on one or two pages, full letter size
(A4)
Data record:
> With optional measurement and interpretation program: ECG measurement
results (intervals, amplitudes, electrical axes), average complexes with
optional measurement reference markings, ECG interpretation statements
> Various format possibilities
Recording tracks: 6 channels, positioned at optimal width on 200 mm,
automatic baseline adjustment
Norms:
Safety standard: CF according to IEC/EN 60601-1 and IEC/EN 60601-2-25,
CSA C22.2 No. 601.1-M90, UL 2601-1
Protection class: I according to IEC/EN 60601-1 (with internal battery)
Classification: lla according MDD 93/42/EEC
Conformity: according to MDD 93/42/EEC
Environmental conditions:
> Temperature, operating: 10° to 40° C / 50° to 104° F
> Temperature, storage: -10° to 50° C / 14° to 122° F
> Relative humidity, operating: 25 to 95 % (non-condensing)
> Pressure, operating: 700 to 1060 hPa
Patient leakage current: < 5 µA
Scope of delivery:
CARDIOVIT AT-2 basic unit with 12-lead Resting ECG
Accessories:
Included:
> 10-lead patient cable
> 500 disposable electrodes or reusable electrode set
> Snapclip adapter for disposable electrodes
> Power cable
> 2 pkg. of recording paper
> Operating manual
Optional:
> Cart (optional)
> Software option: Automatic measurement and interpretation program for
Resting ECGs (intervals, amplitudes, electrical axes, average complexes with
optional measurement reference markings)
*Technical data are subject to change without notice.