Intelect® Legend Stim Two Channel
Electrotherapy System
-
Four Waveforms (Interferential,
Premodulated, High Volt and Russian).
-
Bright back-lit LCD display.
-
Includes Nylatex® wraps, both
red and black 3 round electrodes and lead wires as standard equipment.
-
High Volt available on all
channels.
-
2 Year Warranty.
-
ETL listed and cETL listed.
Stim Waveform Descriptions
Interferential Current
The Interferential waveform
consists of two channels, each with a sinusoidal waveform; one fixed
frequency and one variable frequency. When the four electrodes are positioned
so that the two channels cross each other, the waveforms mix within the
tissue to produce a train of pulses which frequencies and amplitude are
dependent on the sweep mode, beat frequency and amplitude settings,
respectively.
Premodulated
the Premodulated waveform is a
single sine wave that has modulated amplitude. This waveform is similar to
the beat frequency, or pattern created by the Interferential current. In some
cases, Premodulated therapy provides a good alternative for Interferential
treatment, especially when treating areas of the body where four electrodes
can not be utilized.
Russian Current
Medium Frequency Bursted Sine Wave
The Russian current is a 2,500 Hz
sinusoidal carrier wave, interrupted to create a burst of pulses. The burst
frequency sets the number of bursts per second, whereas the duty cycle sets
the duration of the burst. Russian current produces strong comfortable muscle
contractions having the flexibility for use with large and small muscle
groups.
Twin-Peak High Volt Pulsed
Current
The pulse parameters of the
Twin-Peak High Colt current are the factors that allow a great variety of
physiologic responses. The important benefit is versatility in clinical
application. Examples for clinical use include: relaxation of muscle spasms,
prevention or retardation of disuse atrophy, increasing local blood
circulation, muscle re-education, and maintaining or increasing range of
motion. Unlike currents with a very long phase duration, the very short pulse
duration of the Twin-Peak High Volt current creates comfortable stimulation.
The very short pulse duration followed by a very long interpulse interval
eliminates the formation of any appreciable chemical effects in the
stimulated tissue.
|
Stimulator Output Parameters |
|
Parameter |
Interferential |
Premod |
Russian |
High Volt |
|
Carrier Freq. |
5000 Hz |
5000 Hz |
2500 Hz |
|
|
Beat, Burst
or Pulse Freq. |
0-200 |
0-200 |
20-100 |
1-120 |
|
Output Mode |
Pads |
Pads |
Pads |
Pads / Probe |
|
Sweep Time |
15 sec. |
|
|
|
|
Scan Percentage |
40%, 100% |
|
|
|
|
Duty Cycle |
|
|
10, 20, 30, 40, 50% |
|
|
Ramp Up/Down Time |
|
|
0.5-5.0 sec. |
0.5-5.0 sec. |
|
Cycle Time |
|
5/5
Continuous |
5/5
10/10
10/20
4/12
10/30
10/50
Continuous |
5/5
10/10
10/20
4/12
10/30
10/50
Continuous |
|
Polarity |
|
|
|
+, - |
|
Amplitude
Peak |
0-50 mA RMS |
0-50 mA RMS |
1-100 mA RMS |
0-500 V |
|
Treatment Time
(max. min.) |
60 |
60 |
60 |
60 |
|
Available on Channels |
1, 2 |
1, 2 |
1, 2 |
2 |
|
|
| Intelect Combo, Ultrasound
and Stim Units |
| 11-17 VDC, 3A (Ultrasound) and 11-17 VDC, 4A (Stim
and Combo) |
| External Power Supply: 90 - 240 VAC, 50/60 Hz, 50 W |
| Size |
Weight |
| Intelect Stim: 8.5" x 11" x 4" |
4.0 lbs |
|
|