GE Medical Dash 3000 Vital Signs Monitor

SKU: 2580-DSH3-AEAG-AAXX-XXXX
Model: DSH3-AEAG-AAXX-XXXX

In your busy schedule, having accurate patient information at your fingertips is critical. And there is no time for false alarms. With Dash® monitors from GE Healthcare, you get the most accurate patient information in a single, portable platform.

Your price $6,594.83
(you save $1,055.17!)

Found a Lower Price? We'll Beat It!
Call 800.335.3774 for our Price Match Guarantee.

Image may be a representation of product

QTY:
Overview

The RIGHT information. Right now.
In your busy schedule, having accurate patient information at your fingertips is critical. And there is no time for false alarms. With Dash® monitors from GE Healthcare, you get the most accurate patient information in a single, portable platform. Now you can have leading-edge capabilities for complete data virtually anywhere you need it.

With the best selection of gold standard algorithms, Dash monitors reduce false arrhythmia alarms. Dash leads the industry in rejecting artifact from pacemakers. The easy-to-use interface and color-coded patient cables simplify monitor use throughout the hospital. Industry-leading integration and networking capabilities move patient data quickly and reliably throughout the enterprise. With Dash, you can provide unparalleled continuity of care.

A vital TRILOGY.
Dash is based on the critical trilogy of Clinical Excellence, Care Continuity and Knowledge Convergence at the point of decision. These three components work together to support unsurpassed patient care by delivering life-critical data to the bedside, across the hospital and at every point in between. With Dash, it’s as simple as one, two, three.

The future of ALARM management.
Dash monitors incorporate advanced parameters that reduce false alarms, increase accuracy and help you identify cardiac events faster than ever before. With these technologies, Dash can help you provide the best patient care.

Cut out false alarms.
IntelliRate™ is the first algorithm on the market to display heart rate measurements with specific patient data in mind, instead of taking measurements according to standard monitor settings. It rejects inaccurate readings due to noise, pacemaker artifact or low-amplitude QRS complexes in the ECG signal.

IntelliRate considers alarms in context of other parameters, reducing false low heart rate alarms by 72 percent and false asystole alarms by 89 percent, compared with IntelliRate off. By improving the accuracy and reliability of heart rate measurements, this technology reduces needless clinician interruptions, improves workflow and reduces risks ssociated with high false alarm rates.

This is just one example of how GE is setting the pace for alarm management and future healthcare standards.

Accuracy is a heartbeat away.
GE’s two exclusive blood pressure algorithms, DINAMAP® classic and the new SuperSTAT™, improve speed, comfort and artifact rejection while retaining superior accuracy. SuperSTAT combines ECG information with oscillometric data to provide quick and accurate blood pressure readings on any patient – even those with irregular heart rhythms.

The SuperSTAT algorithm, available with the Masimo® Sp02 option, assesses motion artifact to effectively distinguish signal noise. It provides accurate readings even in high-noise environments. SuperSTAT detects NIBP values on the smallest signals, allowing you to obtain blood pressures on any patient, including neonates.

Identify and improve.
Atrial fibrillation (AFib) is the most common arrhythmia that results in hospitalization in the United States. AFib is responsible for significant morbidity and mortality and is a substantial contributor to healthcare expense. Identification of AFib is critical to effectively treat and monitor potential complications. Dash monitors provide AFib detection, allowing you to easily identify and treat atrial fibrillation occurrences, resulting in improved patient outcomes.

The COMPLETE package.
Dash monitors offer a high-performance, mobile monitoring solution that provides life-critical patient data no matter where you are. This technology allows you to remotely view patient information throughout the enterprise. In addition, Dash can be a part of your move to completely integrated patient records.

Good to go.
Extremely easy to use, Dash monitors are versatile enough to implement throughout your enterprise. Lightweight, durable and ergonomic, Dash can be used wherever you need a reliable patient monitor.

Dash monitors move easily from room to room while maintaining connectivity to your network. The color-coded connectors simplify set-up, while the built-in wireless LAN ensures seamless transitions between hard-wired and wireless networking. You can easily add advanced technologies such as the Dash Responder® defibrillator with ease.

Smooth connections to the Dash Port docking station ensure fast transitions. The built-in printer lets you conveniently print strips anytime, anywhere. Long-lasting batteries power Dash for extended use and help support facility-wide portability. In addition, you can change batteries without loss of function.

Connect. Integrate. Communicate.
Now you can have the most complete patient record with connection to the Unity Network® – GE’s real-time patient data network. The Unity Network supports device convergence, data continuity, viewing capabilities and wireless solutions, while providing connectivity to CIC, HIS, CIS, Solar® patient monitors, the MUSE® Cardiology Information System and MARS® Holter review systems.

The Unity Network facilitates integration and continuity by supporting HL7, bedside convergence and platform-to-platform data continuity. The open architecture protects your investments by leveraging existing infrastructure (VLAN), offering compatibility with off-the-shelf components and providing full backwards compatibility. The full-scale features of the Unity Network save the clinician time, manage alarms and provide information anywhere, anytime – all to enable clinical excellence.

Remote monitoring on the fly.
With Auto View on Alarm XM (AVOA XM), you can remotely view alarms and other patient information on beds throughout the care unit. There’s no need for a separate server; the monitors and network handle all the capability. AVOA XM automatically displays user-selected alarms on user-designated bedside monitors. It streamlines your workload and adds another level of customization. The last alarm event, vital signs and graphic trends are accessible for the remotely viewed bed.

Gold standard parameters. Real RESULTS.
  • Marquette® EK-Pro® reduces false arrhythmia alarms to 1 per 5 patient monitor hours.
  • Marquette 12SL™ ECG Analysis Program for Adults and Pediatrics offers simultaneous 12-lead ECG acquisition analysis for uncompromising quality and reliability.
  • Marquette 12SL with Gender-Specific Interpretation features criteria for easy detection of acute myocardial infarction (MI) in female patients.
  • Marquette 12SL with ACI-TIPI (Acute Cardiac Ischemia Time-Insensitive Predictive Instrument) considers a patient’s age, gender and chief complaint as well as ECG measurements to generate a numerical score that helps predict the probability of acute cardiac ischemia.
  • A choice of gold standard SpO2 solutions – Masimo SET® or Nellcor®. • BioZ® Impedance Cardiography (ICG) module for non-invasive hemodynamic data.
  • Smart Anesthesia Multi-gas (SAM®) module for breath-by-breath analysis and instant identification of agents.
  • High-resolution Cardiorespirogram (CRG) trends to detect subtle physiological shifts in neonates.
  • CapnoFlex CO2 monitoring for both mainstream and low-flow sidestream CO2 monitoring.
Specifications

Product Specs
Display
> Size - Dash 3000 – 8.5 in., Dash 4000 – 10.4 in. (diagonal)
> Type - Active-matrix color LCD
> Resolution - 640 by 480 pixels
> Number of traces - 6 (maximum)
> Number of seconds/trace - 4.9 at 25 mm/sec
> Sweep speed - 6.25, 12.5, 25 mm/sec (with erase bar)

Controls
> TrimKnob® control
> Five hard keys - Silence Alarm, Graph Go/Stop, NBP Go/Stop, Zero All and Power On/Off
> Remote control option - Available

Alarms
> Categories - Patient status and system status
> Priority - 4 levels – Crisis, Warning, Advisory and Message
> Notification - Audible and visual
> Setting - Default and individual
> Silencing - 1 minute, current alarm only
> Pause - 5 minutes in Adult ICU mode, 3 minutes in Neonatal ICU mode and 5 minute, 15 minute, or permanent pause in OR mode
> Volume - Default 70 dB measured at 1 meter

Invasive Blood Pressure
> Number of channels - 1 to 4 (optional); 3rd and 4th invasive lines only available with Masimo® SpO2
> Transducer sites - Arterial, femoral artery, pulmonary arterial, central venous, right atrial, left atrial, intracranial and special
> Transducer requirements - Excitation voltage: 5 V dc ± 0.1%
> Transducer output - 5 μV/V/mmHg

Input Specs
> Range - -25 mmHg to 300 mmHg
> Offset - ± 150 mmHg

Output Specs
> Frequency response - dc to 50 Hz (-3 dB)
> Zero balance range - ± 150 mmHg
> Zero balance accuracy - ± 1 mmHg
> Zero balance drift - ± 1 mmHg over 24 hours
> Accuracy - ± 2% or ± 1 mmHg, whichever is greater (exclusive of transducer)
> Alarms - User-selectable upper and lower limits for systolic, diastolic and mean pressures

ECG
> Standard leads available - I, II, III, V, aVR, aVL and aVF
> 3, 5 and 10 leadwire cable - I, II, III, V, aVR, aVL, aVF, V2, V3, V4, V5 and V6
> Leads analyzed simultaneously - I, II, III and V (multi-lead mode)
> Lead fail - Identifies failed lead
> Alarms - User-selectable upper and lower heart rate limits

Input Specs
> Voltage range - ± 0.5 mV to ± 5 mV
> Signal width - 40 ms to 120 ms (Q to S)
> Heart rate range 3- 0 to 300 bpm
> Input impedance -
Common mode > 10 MΩ at 50/60 Hz
Differential > 2.5 MΩ from dc to 60 Hz
Common mode rejection 90 dB minimum at 50 or 60 Hz

Output Specs
> Impulse response -
For an impulse of 3 mV applied for 100 ms
Displacement following impulse < 0.1 mV
Slope following impulse < 0.3 mV/s
> Frequency response -
Response of non-permanent displays is limited by resolution
to 40 Hz (-3 dB) @25 mm/s. Specified upper frequency
limits may vary by ± 2 Hz.
> Diagnostic mode - 0.67 Hz (+0.4 dB) to 100 Hz (-3 dB)
> For compliance with China National Standard - 1.0 Hz (+0.4dB) to 75 Hz (-3 dB)
> Monitoring mode - 0.67 (+0.4 dB) to 40 Hz (-3 dB)
> Moderate mode - 0.67 (+0.4 dB) to 25 Hz (-3 dB)
> Maximum mode - 5.0 Hz (-0.3 dB) to 25 Hz (-3 dB)
> Noise - < 30 μV (referred to input)

Pacemaker detection/rejection
> Input voltage range - ± 2 mV to ± 700 mV
> Input pulse width - 0.1 ms to 2 ms
> Rise time - 10 μs to 100 μs
> Over/under shoot - 2 mV (max)
> Baseline drift - < 0.5 mV per hour with a ± 700 mV, 2 ms
> Pacemaker pulse - Applied<

Respiration
> Measurement technique - Impedance variation detection
> Range - 0-200 breaths per minute for variations of 1.0 – 10.0 Ω
> Respiration rate - 0-200 breaths per minute
> Base impedance - 100-1000 Ω at 52.6 kHz
> Detection sensitivity - 0.4 to 10 Ω variation
> Waveform display bandwidth - 0.1 to 1.8 Hz (-3 dB)
> Alarms - User-selectable upper and lower respiration rate limits, and
user-selectable apnea limit

Temperature
> Number of channels - 2

Input Specs

> Probe type - YSI Series 400 or 700 (determined by input cable)
> Temperature range - 0°C to 45°C (32°F to 113°F)
> Resolution - ± 0.1°C

Output Specs
> Parameters displayed - T1, T2
> Accuracy (independent of source) - ± 0.1°C for YSI series 400
> Probes - ± 0.3°C for YSI series 700 probes
> Alarms - User-selectable upper and lower limits for T1, T2
 

Cardiac Output
Input Specs
> Probe type - In-line or bath probe
> Catheter size - 5F, 6F, 7F, 7.5F and 8F
> Injectate volume - 3, 5 or 10 cc

Output Specs
> Parameters displayed - Cardiac output, blood temperature, injectate temperature and trial number

Range
> Cardiac output - 0.2-15 (liters per minute)
> Blood temperature - 30-42°C
> Injectate temperature - 0-30°C

Accuracy
> Cardiac output - ± 5%
> Blood temperature - ± 0.2°C
> Injectate temperature - ± 0.3°C
> Frequency response - dc to 15 Hz ± 2 Hz
 

Pulse Oximetry
> Parameters monitored - Arterial oxygen saturation (SpO2) and peripheral pulse rate (PPR)
> SpO2 range - Nellcor®-compatible 50-100%; Masimo 30-100%
> PPR range - Nellcor-compatible 30-300 BPM; Masimo 25-240 BPM
> Accuracy - Actual accuracy depends on probe. Please reference manufacturer’s specifications.
> Nellcor compatible SpO2 - ± 2% (70-100% SpO2); ± 3% (50-69% SpO2)
> Masimo SpO2 - ± 2% Adults/Pediatric (70-100% SpO2); SpO2 ± 3% Neonates ≤ 69% unspecified
> PPR - ± 3 beats per minute
> Alarms - User-selectable upper and lower limits for SpO2 and PPR

DINAMAP® Non-Invasive Blood Pressure
> Technology - DINAMAP classic and SuperSTAT™ (SuperSTAT only available with Masimo SpO2)
> Measurement technique - Oscillometric
> Displayed parameters - Systolic, diastolic and mean pressures, time of last measurement
> Measurement modes - Adult ICU and OR modes; manual, auto and stat, neonatal mode; manual and auto

Systolic
> Adult - 30-285 mmHg
> Pediatric - 30-235 mmHg
> Neonate - 30-140 mmHg

Map
> Adult - 20-260 mmHg
> Pediatric - 20-220 mmHg
> Neonate - 20-125 mmHg

Diastolic
> Adult - 10-220 mmHg
> Pediatric - 10-210 mmHg
> Neonate - 10-110 mmHg

Pulse rate, as displayed in tabular trends
> Adult - 30-200 bpm
> Pediatric - 30-200 bpm
> Neonate - 30-220 bpm

Other Specs
> Overall system accuracy - Meets or exceeds SP 10-1992 AAMI standards
> Automatic cycle times - 0-8 hours
> Tubing length - 12 feet adult, 8 feet neonatal
> Automatic cuff deflation -
Cycle time exceeding 3 minutes (90 seconds neonatal), French mode – Cycle time exceeding 2 minutes (60 secondsneonatal), power off, or cuff pressure exceeds 294 mmHg (± 6 mmHg) adult, 250 (± 5 mmHg) pediatric, 147 (± 3 mmHg) neonatal
> Cuff sizes - Thigh, large adult, adult, small adult, child, infant and neonatal, sizes #5 - #1 and assorted long sizes
> Alarms - User-selectable upper and lower limits for systolic, diastolic and mean pressures

CO2
Technology
> Supports Novametrix CapnoStat (mainstream) and LoFlo (low-flow sidestream) CO2 technologies
> Principle of operation - Non-dispersive infrared (NDIR) single beam optics, dual wavelength and no moving parts
> Warm-up time - 2 minutes warm-up time to meet accuracy specifications; waveform immediate upon power up, calculated end tidal after two breaths
> Cable length (mainstream) - 8 foot (2.4 m)
> Sample line length (low-flow sidestream) - 7 foot (2.1 m)

Information Displayed
> Inspired and expired CO2 concentrations in %, mmHg or kPa; respiratory rate, continuous CO2 waveform

Measurement range (at 760 mmHg at an ambient temperature of 25°C)
> 0-100 mmHg, 0-13%, 0-12.5 kPa
> PiCO2 /FiCO2 - 0-50 mmHg, 0-6.5%, 0-6.25 kPa
> Respiration rate range - Low-flow SS 0-150 breaths/min
> Mainstream - 0-120 breaths/min

Accuracy (at 760 mmHg at an ambient temperature of 25°C)
> MS -
±2 mmHg or 5%, whichever is greater
SS 0-40 mmHg ± 2 mmHg; 41-70 mmHg ± 5% of reading; 71-100 mmHg ± 8% of reading; all specifications ± 12% of actual from 80-150 BrPM
> Display resolution - 1 mmHg
> Rise time - Less than 200 ms (low-flow sidestream); less than 60 ms (mainstream adult reusable or SPU); less than 50 ms (mainstream infant reusable or SPU)
> Respiration rate accuracy - ± 1 breath/min

Compensations
> Automatic barometric pressure - ± 25 mmHg from 530-785 mmHg
> Operator-selectable O2/N2O compensation

Calibration
> Mainstream -
No routine user calibration required
15 second airway adapter zero performed when changing to a different style of airway adapter
> Low-flow sidestream - No routine user calibration required

Airway adapters and sample lines – mainstream (airway adapters)
> Types - Adult reusable (standard), adult disposable, infant
> Deadspace -
Adult reusable/disposable < 5 cc
Infant disposable < 1 cc
Taper meets ISO 5356-1

Low-flow sidestream airway adapters
> Types - Adult reusable (standard), adult disposable, infant
> Deadspace -
Adult reusable/disposable < 7.3 cc
Infant disposable < 1 cc

Low-flow sidestream sample lines
> Adult, pediatric and infant - Nasal CO2 and nasal CO2/O2
> Adult and pediatric - Nasal/oral CO2 and nasal/oral CO2/O2

Alarms
> CO2 - High inspired CO2; high/low expired CO2
> Respiratory rate Adjustable high and low
 

Paper Recorder
> Method - Thermal dot array
> Horizontal resolution - 480 dots/in. @25 mm/sec.
> Vertical resolution - 200 dots/in.
> Number of waveform channels - four
> Paper width - 50 mm (1.97 in.)
> Paper length - 30 m (100 ft.)
> Paper speed - 0.1, 0.5, 1, 5, 10, 12.5, 25 and 50 mm/sec. (± 2%)

Analog Output
ECG
> Gain - 1 V/mV ± 10%
> DC offset - ± 100 mV (max)
> Noise - < 5 mV peak to peak 0-300 Hz
> Frequency response - Refer to Frequency Response section under ECG

Blood pressure
> Gain - 10 mV/mmHg ± 2%
> DC offset - ± 20 mV (max)
> Noise - < 5 mV peak to peak 0-300 Hz
> Frequency response - dc to 50 Hz-0/+2 Hz
 

Battery
> Battery type - Exchangeable Lithium-Ion
> Maximum number of batteries - 2
> Voltage - 11.1 V (nominal)
> Capacity - ≥ 3.45 Ah (varies with manufacturers)
> Charge time - Less than 4 hours each
> Run time - 4 to 5 hours
> Battery life - 500 cycles to 50% capacity

Wireless LAN
> Operating frequency - 2.4 to 2.5 GHz
> Transmit power - 100 mW
> Data rate - 1Mbps and 2Mbps per channel
> Radio technology - Frequency-hopping spread spectrum
> Communication protocol - IEEE 802.11
> UL 1950 Listed (ITE 9B97), CE Mark RF Standard
> US - FCC Part 15 Class B, Europe: ETS 300 328 and ETS 300 826

Environmental Specifications
> Power requirements -
90-132 VAC 50/60 Hz 2.0A
190-264 VAC 50/60 Hz 1.0A
> Power consumption - 75 W (fully loaded)
> Cooling - Convection
> Heat dissipation - 240 Btu/hr. (max)

Operating Conditions
> Ambient temperature - 0-40°C (32-104°F)
> While charging batteries - 0-35°C (32-95°F)
> CO2 sensor - 10-40°C (50-104°F)
> Relative humidity - 5-95% @40°C
> Vibration - MIL-STD 810E, Method 514.4, Category 1
> Altitude - -273 m to 2,943 m (-896 to 9,655 ft.)

Storage Conditions
Do not exceed
> Maximum - 70°C (158°F) at 95% relative humidity
> Minimum - -40°C (-40°F)
> CO2 sensor - -30 to 65°C (-22 to 149°F)
> Batteries - -20 to 60°C (-4 to 140°F)
 

Physical Specifications
> Height - 26 cm (10.25 in.)
> Depth - 20 cm (8 in.)
> Width - 28 cm (11.0 in.)
> Weight - 5.08 kg (11.2 lbs.)

Warranty
> Standard warranty is one year.

Ordering Options
DASH3-AEAG-AAXX-XXXX - GE Medical Dash 3000 Vital Signs Monitor
Bedside w/GE Ohmeda SpO2, Standalone - Non-Networked Patient Monitor, English, (1) Lithium-Ion Internally or Externally Rechargeable Battery, 4-Channel Integrated Thermal Printer, Standard Handle, Adult NIBP Hose, DURA-CUF Assortment Pack (Various Sizes - Bx/6), Nellcor Interface Cable, Multi-link ECG Cable, Multi-link 3 Leadwires, 1 Year Warranty
ConditionNew
Manufacturer GE Healthcare

My Cart

You currently have 0 Products in your shopping cart.

Rest Assured...

Why buy from MedSupplier.com?
  • Authorized Dealer
  • Price Match Guarantee
  • Knowledgable Sales Reps
  • No Black Market Products

We do what those other guys can't by being an authorized dealer and providing knowledgable sales representatives and an experienced customer service team.

There are no black market products in our catalog because they come straight from the manufacturer, so you know you are getting a geniune product.