0 Products $0.00

Free Shipping  with most orders over $100! Shipping Policy

Forest Medical Trillium 5000 Holter System

List Price: $6,599.00
Your Price: $3,740.00
MSC Points: 374 - Learn more about our Loyalty Points Program
QTY:

Already have a List? Sign In

Our Trillium 5000 Holter Recorder is combined with our Trillium Gold Holter Analysis Software to form a complete and comprehensive...

ConditionNew
SKU 2540-09N-0401-324
Reviews
Manufacturer Forest Medical Authorized Dealer
Overview
Features:
  • Widely Accepted Diagnostic Procedure
  • Proven eidos Holter Algorithm
  • LCD Display
  • Pacemaker Detection
  • 1 Year Warranty
  • Gold Analysis Software
  • Discover the Value Leader in Holter
  • Forest Medical Holter Monitoring Systems are surprising affordable and provide the best long term value in Holter monitoring technology.

Gold Analyzer Software - Power That's Easy To Use
Our Trillium Gold™ Holter Analysis Software provides flexible and accurate analysis, expanded functionality, powerful editing capabilities, and configurable and editable reports to give you the information you need to provide the best possible patient care.

Trillium Gold Holter Analysis Software is based on our proven eidos™ Holter Algorithm and provides complete support for pediatric through adult applications including pacemaker detection and reporting.

Choice of Recorders
Trillium Gold Holter Analysis Software can be used with our new Trillium 4000 and Trillium 5000 Holter Recorders.

Trillium Gold based Holter Monitoring Systems are easily and economically expandable with multiple recorders and workstations and are fully upgradeable. By choosing Forest Medical, you can be sure that you’ve made the right investment in Holter monitoring technology now and for the future.

Specifications

Trillium 5000 Holter Recorder Specifications
> Channels: 2 or 3
> Recording Time: 24 or 48 Hours
> Recording: Continuous (Full Disclosure)
> Memory: Non-volatile Flash-Card
> Resolution: 10-bit sampling
> Sample Rate: 512 samples per second per channel
> Frequency Response: 0.05 Hz – 60 Hz
> Gain Settings: 1/2X, 1X, and 2X
> Power Requirements: (1) AA Alkaline IEC-LR6
> Overall size: 2.78 x 3.75 x 0.78 inches (88.9 x 162.6 x 24.1 mm)
> Weight Including Batteries: 4 ounces (112 grams)
> Operating Temperature: 32° F to 113° F (0° C to 45° C)
> Non-operating Temperature: -4° F to 149° F (-20° C to 65° C)
> Operating Humidity: 10% to 95% (non-condensing)
> Non-operating Humidity: 5% to 95% (non-condensing)
> Patient Cable: 5 or 7 Lead
> Signal Verification: LCD Display - ECG Display on LCD
> Five button keypad operation with LCD Display
> Meets the ANSI/AAMI standard for ambulatory electrocardiographs (EC38) including pacemaker and use for infants
> Unlimited Toll Free Technical Support

Reporting Capabilities
Overview
> 32 Bit Windows® Application
> Point and click, web browser-like operation
> Each report page is displayed on screen
> Color-coded arrhythmias
> Color-coded pacer spikes
> No limit to number of patient files that can bestored on disk
> MCR File –“report-only” file (typ. <100 KB)
> On-screen help, tutorial, and hints

Editing
> Enter Cover Page data
> Reconfigure Cover Page
> Delete or add Report Strips
> Delete or add individual episodes, or delete all episodes
> Change individual existing beat label
> Insert a beat
> Artifact Category Designation
> Designate Artifact from Full Disclosure
> Manually Designate Paced Beats
> Report data is automatically recalculated
> Parameter Settings
> Change Report Strip Label
> Change Form Label

Pacemaker Detection / Reporting

Superimposition
> One or two beats
> Variable rate scanning
> One beat or one minute jog-back/jog-forward
> Automatic jog-back based on user reaction time
> R-R histogram or tachogram side display

Q-T Interval Measurement
> Graph
> Superimposition
> Editing
> Raw
> Corrected
> Auto Q-T Calipers

R-R Interval Measurement
> Shortest and Longest R-R Interval
> Time-domain Heart Rate Variability statistics

On-Screen Calipers
> Measure time intervals or ST level
> Caliper Interval Repeat
> Calipers can be saved with strip
> Show Rate Measurements
> Show R-R Interval Measurements

Report
> Memory Card Data (MCD) File Storage
> Memory Card Report (MCR) File Storage
> Copy / paste text into Windows clipboard
> Copy / paste graphs into Windows clipboard
> Customize Report Layout
> One Page Report

Cover Page
> Patient Information
> Medications / Symptoms
> Print Logo
> Physician Information
> Referring Physician Information
> Conclusions
> Parameter Settings
> ICD-9 CM Drop Down Box

Narrative Summary
> Initial Signal Quality
> Total QRS Complexes
> Average, Maximum, and Minimum Heart Rate
> Total Ventricular Ectopic Beats (VE)
> Isolated Ventricular Ectopic Beats
> Bigeminy, duration
> Trigeminy episodes
> Couplets (VE Pairs)
> Ventricular Runs, duration, longest and fastest
> Idio-ventricular Rhythm (<100 BPM)
> Total Supraventricular Ectopic Beats (SVE)
> Isolated Supraventricular Ectopic Beats
> SVE Pairs
> SV Bigeminy
> SV Trigeminy
> Supraventricular Tachycardia (SVT), duration, longest and fastest
> Irregular Rhythm, duration
> Tachycardia, duration
> Bradycardia, duration
> Pauses (Asystole)
> Longest Pause (Asystole)
> ST Depression / Elevation
> Patient Events
> Pacemaker Analysis (Total Paced Beats, Failure to Capture, Failure to Sense)

Hourly Summary
> Customizable
> Average, Maximum, and Minimum Heart Rate
> Isolated Ventricular Ectopic Beats
> Bigeminy
> Trigeminy
> Couplets (VE pairs)
> Ventricular Runs
> Isolated Supraventricular Ectopic Beats
> SVE Pairs
> SV Bigeminy
> SV Trigeminy
> Supraventricular Tachycardia (SVT)
> Tachycardia
> Irregular Rhythm
> Bradycardia
> Pauses (Asystole)
> ST Depression / Elevation
> Patient Events

Graphs
> Heart Rate
> Ventricular Ectopics
> Ventricular Runs
> Supraventricular Ectopics
> Supraventricular Tachycardia
> Artifact Index (2 or 3 channel)
> ST Level (2 or 3 channel)
> Normal R-R Histogram
> Abnormal R-R Histogram
> Pacer Rate
> Pacer R-R Histogram
> Q-T Graph
> Pause Graph

Ventricular Forms
> Beat Count and Sample of up to 32 Ventricular Forms
> Beat Count and Sample of up to 32 Normal Forms
> Reclassify Forms by Prematurity and Shape
> Turn off a channel

Strips
> Automatic Report Strips in full-scale (25 mm/sec) or mini-scale (8.5 mm/sec) format
> Automatic Report Strips 8, 18, or 32 per page
> Strip List
> Extract strip from any time in the monitoring period
> Extract all strips for an episode type

Full Disclosure
> Print in 1 Hour Increments
> 15, 30, or 60 seconds per line
> 1 Channel Only
> Any combination of 2 or 3 channels
> Patient event indicated by circle
> Information at end of line (HR, VEs, ST, SVEs)

Alternate Outputs
> Graphs bitmapped to clipboard
> Text bitmapped to clipboard

Analysis Algorithm
> Forest Medical eidos™ Holter Algorithm
> Adjustment for Atrial Fibrillation / Irregular Rhythm sensitivity

Pediatrics
> Rate Parameter Settings
> High Rate Algorithm
> Under 20 kg Patients

Electronic Medical Records Support

Ordering Options

Forest Medical Trillium 5000 Holter System

09N-0401-324 - Forest Medical Trillium 5000 Holter System
Includes: Trillium 5000 Recorder, Trillium Gold Analyzer Software, 1 Year Warranty

Customer Reviews

No one has reviewed this product yet. Be the first to write a review.

Write a Review

Already own this product? Tell us what you think about it.

Rating  



Review  
Name  
Email  

Image may be a representation of product

Financing Options

MedSupplier.com has many special financing programs with flexible terms and payment options to get you the equipment you need.

Finacing Application

Found A Lower Price?

We try hard to offer the lowest delivered price on all of the products we carry.

If you have found a lower price somewhere else, let us know here.

Why Buy From Us?

  • Price Match Guarantee
  • Authorized Dealer
  • Knowledgable Sales Reps
  • No Black Market Products

We do what those other guys can't by being an authorized dealer and providing knowledgable sales representatives and an experienced customer service team.

There are no black market products in our catalog because they come straight from the manufacturer, so you know you are getting a geniune product.