Trillium 2000 Holter Recorder Specifications
> Channels: 2 or 3
> Recording Time: 24 Hours
> Recording: Continuous (Full Disclosure)
> Memory: Non-volatile Flash-Card
> Resolution: 12-bit sampling
> Sample Rate: 256 samples per second per channel
> Frequency Response: 0.05 Hz – 100 Hz
> Gain Settings: Automatic per channel
> Power Requirements: (3) AA Alkaline IEC-LR6
> Overall size: 3.5 x 6.4 x 0.9 inches (88.9 x 162.6 x 22.8 mm)
> Weight Including Batteries: 10.75 ounces (305 grams)
> Operating Temperature: 32° F to 113° F (0° C to 45° C)
> Non-operating Temperature: -4° F to 149° F (-20° C to 65° C)
> Operating Humidity: 10% to 95% (non-condensing)
> Non-operating Humidity: 5% to 95% (non-condensing)
> Patient Cable: 5 or 7 Lead
> Signal Verification: Multi-color LEDs and Test Strips
> Three button operation with 16 character LCD display
> Time and Parameter Settings: 5 Year Lithium battery backup
> Meets the ANSI/AAMI standard for ambulatory electrocardiographs (EC38)
> Unlimited Toll Free Technical Support
Reporting Capabilities
Overview
> Windows 32 Bit (Win 98 SE and beyond)
> Point and click, web browser-like operation
> Each report page is displayed on screen
> Color-coded arrhythmias
> No limit to number of patient files that can be stored on disk
> On-screen help, tutorial, and hints
Editing
> Enter Cover Page data
> Delete or add Report Strips
> Delete or add individual episodes, or delete all episodes
> Designate Artifact from Full Disclosure
> Report data is automatically recalculated
> Parameter Settings
> Change Report Strip Label
On-Screen Calipers
> Measure time intervals or ST level
> Caliper Interval Repeat
> Calipers can be saved with strip
Report
> Memory Card Data (MCD) File Storage
> One Page Report
Cover Page
> Patient Information
> Medications / Symptoms
> Physician Information
> Conclusions
> Parameter Settings
> Initial Signal Quality
> ICD-9 CM Drop Down Box
Narrative Summary
> Initial Signal Quality
> Total QRS Complexes
> Average, Maximum, and Minimum Heart Rate
> Total Ventricular Ectopic Beats (VE)
> Isolated Ventricular Ectopic Beats
> Bigeminy, duration
> Trigeminy episodes
> Couplets (VE Pairs)
> Ventricular Runs, duration, longest and fastest
> Total Supraventricular Ectopic Beats (SVE)
> Isolated Supraventricular Ectopic Beats
> SVE Pairs
> SV Bigeminy
> SV Trigeminy
> Supraventricular Tachycardia (SVT), duration, longest and fastest
> Irregular Rhythm, duration
> Tachycardia, duration
> Bradycardia, duration
> Pauses (Asystole)
> Longest Pause (Asystole)
> ST Depression / Elevation
> Patient Events
Hourly Summary
> Average, Maximum, and Minimum Heart Rate
> Isolated Ventricular Ectopic Beats
> Bigeminy
> Couplets (VE pairs)
> Ventricular Runs
> Isolated Supraventricular Ectopic Beats
> Supraventricular Tachycardia (SVT)
> Tachycardia
> Bradycardia
> Pauses (Asystole)
> ST Depression / Elevation
> Patient Events
Graphs
> Heart Rate
> Ventricular Ectopics
> Ventricular Runs
> Supraventricular Ectopics
> Supraventricular Tachycardia
> Artifact Index (2 or 3 channel)
> ST Level (2 or 3 channel)
> Normal R-R Histogram
> Abnormal R-R Histogram
Ventricular Forms
> Beat count and sample of up to eight Ventricular Forms
Strips
> Automatic Report Strips in full-scale (25 mm/sec) or mini-scale (8.5 mm/sec)
format
> Automatic Report Strips 8, 18, or 32 per page
> Strip List
> Extract strip from any time in the monitoring period
> Extract all strips for an episode type
Full Disclosure
> Print in 1 Hour Increments
> 15, 30, or 60 seconds per line
> 1 Channel Only
> Any combination of 2 or 3 channels
> Patient event indicated by circle
Electronic Medical Records Support