Forest Medical Trillium 1000 Direct To Printer Holter Overview
Features:
- Direct To Printer
- No PC Required
- Widely Accepted Diagnostic Procedure
- Proven eidos Holter Algorithm
- Qualifies for Maximum Reimbursement
- 2 Year Warranty
- On-board Analysis Capabilities
Get Started with Direct to Print
With its simplified operation and unique direct to print capabilities, the
Trillium 1000 Holter Recorder/Analyzer lets you get started with only a
printer. With easy to understand hookup quality verification, and automatic
report generation at the end of monitoring, information is available
immediately upon patient return for your review. By using the front mounted
buttons and LCD display, you can easily select only the information you need
to make diagnostic decisions quickly.
Discover the Value Leader in Holter
All Forest Medical Holter monitoring products are surprising affordable and
provide the best value in Holter monitoring technology. Our Trillium 1000
Holter Recorder/Analyzer is extremely rugged and comes with a two year
warranty and unlimited toll free technical support.
Qualify for Maximum Reimbursement
The Trillium 1000 Holter Recorder/Analyzer can be used to provide Holter
diagnostic procedures that qualify for maximum reimbursement (CPT Code 93230).
Enhance Patient Retention
The diagnostic procedures that can be performed with the Trillium 1000 Holter
Recorder/Analyzer can be used as screening tools to determine if a referral to
another provider is actually required.
By reducing the number of unnecessary referrals you can enhance patient
retention and improve patient satisfaction with your service while
simultaneously helping to reduce the overall cost of healthcare
Trillium 1000 Holter Recorder/Analyzer Specifications
Channels: 2 or 3
Recording Time: 24 Hours
Recording: Continuous (Full Disclosure)
Memory: Non-volatile Flash-Card
Resolution: 12-bit sampling
Sample Rate: 256 samples per second per channel
Frequency Response: 0.05 Hz – 100 Hz
Gain Settings: Automatic per channel
Power Requirements: (3) AA Alkaline IEC-LR6
Overall size: 3.5 x 6.4 x 0.9 inches (88.9 x 162.6 x 22.8 mm)
Weight Including Batteries: 10.75 ounces (305 grams)
Operating Temperature: 32° F to 113° F (0° C to 45° C)
Non-operating Temperature: -4° F to 149° F (-20° C to 65° C)
Operating Humidity: 10% to 95% (non-condensing)
Non-operating Humidity: 5% to 95% (non-condensing)
Patient Cable: 5 or 7 Lead
Signal Verification: Multi-color LEDsand Test Strips
Three button operation with 16 character LCD display
Time and Parameter Settings: 5 Year Lithium battery backup
Meets the ANSI/AAMI standard for ambulatory electrocardiographs (EC38)
Unlimited Toll Free Technical Support
Reporting Capabilities
Editing
> Delete or add Report Strips
> Delete or add individual episodes, or delete all episodes
> Parameter Settings
Cover Page
> Includes Blanks for Patient Information, Medications/Symptoms, Physician
Information,
Conclusions
> Provides Parameter Settings and Initial Signal Quality Information
Narrative Summary
> Total QRS Complexes
> Average, Maximum, and Minimum Heart Rate
> Total Ventricular Ectopic Beats (VE)
> Isolated Ventricular Ectopic Beats
> Bigeminy, duration
> Couplets (VE Pairs)
> Ventricular Runs, duration, longest and fastest
> Total Supraventricular Ectopic Beats (SVE)
> Isolated Supraventricular Ectopic Beats
> SVE Pairs
> Supraventricular Tachycardia (SVT), duration, longest and fastest
> Irregular Rhythm, duration
> Tachycardia, duration
> Bradycardia, duration
> Pauses (Asystole)
> Longest Pause (Asystole)
> ST Depression / Elevation
> Patient Events
Hourly Summary
> Average, Maximum, and Minimum Heart Rate
> Isolated Ventricular Ectopic Beats
> Bigeminy
> Couplets (VE pairs)
> Ventricular Runs
> Isolated Supraventricular Ectopic Beats
> SVE Pairs
> Supraventricular Tachycardia (SVT)
> Tachycardia
> Bradycardia
> Pauses (Asystole)
> ST Depression / Elevation
> Patient Events
Graphs
> Heart Rate
> Ventricular Ectopics
> Ventricular Runs
> Supraventricular Ectopics
> Supraventricular Tachycardia
> Artifact Index (2 or 3 channel)
> ST Level (2 or 3 channel)
> Normal and Abnormal R-R Histograms
Strips
> Automatic Report Strips in full-scale (25 mm/sec) and mini-scale (8.5
mm/sec) formats
> Extract strip from any time during monitoring
> Extract all strips for an episode type
Full Disclosure
> Print in 1 Hour Increments
> 60 or 30 seconds per line
> 1 Channel only or any combination of 2 or 3 channels
> Patient event indicated by circle